TPS3813K33DBVT this integrated circuit is available in factory sealed anti static packs. at icwhale.com. Please read product page below detail information. including TPS3813K33DBVT price, data-sheet, in-stock availability, technical difficulties. Also. Quickly Enter the access of compare listing to find out replaceable electronic parts. If you want to retrieve comprehensive data for TPS3813K33DBVT to optimize the supply chain (including cross references, life-cycle, parametric, counterfeit risk, obsolescence managements forecasts), please contact to our Tech-supports team.
There is no doubt that you may place an order without registering to icwhale.com.
We strongly suggest you sign in our shop before purchasing as you can track your order real-time tracking.
For your convenience, we support multiple payment methods in USD, including PayPal, Credit Card, wire transfer. and Alipay.
It is recommended to acquire for quotations to get the latest prices and inventories about the parts.
Our sales will reply to your request by email within 24 hours.
1. You'll receive an order information email in your email inbox. (Please remember to check the spam folder if you didn't hear from us).
2. Since inventories and prices may fluctuate to some extent, the sales manager is going to reconfirm the order and let you know if there are any updates.
Shipping fee starts at $35, but some countries will exceed $35. For example (South Africa, Brazil, India, Pakistan, Israel, etc.)
The basic freight (for package ≤0.5kg or corresponding volume) depends on the time zone and countries.
Currently, our products are shipped through DHL, FedEx, SF, UPS and China Post.
Once your order has been shipped, the tracking number will be sent to the email address registered to your account. This information can also be viewed when logged into your account in the "my account" page.
Views:
Application Scenarios
1. Medical Equipment: To ensure stable operation of sensitive medical devices by monitoring their power supplies.
2. Data Storage Systems: In data centers, monitor the voltage supplied to storage devices and servers for consistent performance.
Key Parameters and Characteristics
- Fixed Voltage Monitoring: Offers precise supervision of specific voltage levels.
- Low Power Consumption: Suitable for systems where energy efficiency is a priority.
- Push-Pull Reset Output: Provides a clear output signal for system resets.
- Compact Package: Ideal for space-limited applications.
Detailed Circuit Connection for Medical Equipment
1. Voltage Monitoring Input (VDD Pin): Connect this pin to the voltage rail of the medical device that needs to be monitored, like the main power supply line.
2. System Ground Connection (GND Pin): Attach the TPS3813K33DBVT GND pin to the device's ground to establish a stable reference point.
3. Reset Output (RESET Pin): This pin outputs a signal when the monitored voltage falls out of the threshold range. Connect it to the control circuitry to initiate corrective actions or resets.
4. Power Supply (VCC Pin): Link this pin to a regulated power source that powers the supervisory circuit.
5. Stabilization (Bypass Capacitor): Place a bypass capacitor between the VCC and GND pins to stabilize the IC and filter noise.
6. Delay Configuration (CT Pin): A capacitor connected to this pin sets the delay time for the reset signal, allowing customization based on system requirements.
7. Manual Testing (TEST Pin): Use this pin for manually trigger the reset function, important for system checks and diagnostics.
Design Considerations
- Reliable Power Source: Essential for accurate voltage monitoring in critical medical applications.
- Threshold Setting Precision: The TPS3813K33DBVT voltage threshold needs to be accurately set for effective supervision.
- Noise Reduction: Implementing filtering strategies to prevent false triggering due to voltage spikes.
- System Integration: The TPS3813K33DBVT reset signal should be correctly interfaced with the medical device's control system.
- Adjustment of Reset Timing: Select the appropriate capacitor for the CT pin to tailor the reset delay.
- Thermal Management: Maintain optimal operating temperatures, despite the IC's low power consumption.
Integrating the TPS3813K33DBVT into medical equipment involves thorough planning around these factors. Its role as a voltage supervisor is critical in medical applications, where precise voltage regulation is vital for the safety and reliability of the equipment.
Currently, icwhale.com only provide peer-to-peer order processing. While you submit the RFQ, our professional agent will contact you with the competitive prices in the global market, and our agent will prompt you to finish the order if you accept our offers.
We have a professional and experienced quality control team to strictly verify and test the TPS3813K33DBVT. All suppliers must pass our qualification reviews before they can publish their products including TPS3813K33DBVT on icwhale.com; we pay more attention to the channels and quality of TPS3813K33DBVT products than any other customer. We strictly implement supplier audits, so you can purchase with confidence.
The price and inventory of TPS3813K33DBVT fluctuates frequently and cannot be updated in time, it will be updated periodically within 24 hours. And, our quotation usually expires after 5 days.
Wire Transfer, PayPal, Alipay, Wechat, Credit Card, Western Union, MoneyGram, and Escrow are all acceptable.
Warm Tips: Some orders in certain payment forms may require handling fee.
Customers can choose industry-leading freight companies, including DHL, UPS, FedEx, TNT, and Registered Mail. Shipping insurance is also available.
Once your order has been processed for shipment, our salesperson will send you an email advising you of the shipping status and tracking number.
Warm Tips: It may take up to 24 hours for the carriers to display tracking information. Usually, express delivery takes 3-5 days, and registered mail takes 25-60 days.
All goods will implement Pre-Shipment Inspection (PSI), selected at random from all batches of your order to do a systematic inspection before arranging the shipment. If there is something wrong with the TPS3813K33DBVT we delivered, we will accept the replacement or return of the TPS3813K33DBVT only when all of the below conditions are fulfilled:
(1)Such as a deficiency in quantity, delivery of wrong items, and apparent external defects (breakage and rust, etc.), and we acknowledge such problems.
(2)We are informed of the defect described above within 90 days after the delivery of TPS3813K33DBVT.
(3)The PartNo is unused and only in the original unpacked packaging.
Two processes to return the products:
(1)Inform us within 90 days
(2)Obtain Requesting Return Authorizations
If you need any after-sales service, please do not hesitate to contact us.
ON Semiconductor
Analog Devices Inc.
ON Semiconductor
Analog Devices Inc.
Analog Devices Inc./Maxim Integrated
Analog Devices Inc./Maxim Integrated
Analog Devices Inc./Maxim Integrated
Analog Devices Inc./Maxim Integrated
Analog Devices Inc./Maxim Integrated
Analog Devices Inc./Maxim Integrated
Analog Devices Inc.
Texas Instruments
Analog Devices Inc./Maxim Integrated
Analog Devices Inc./Maxim Integrated
ON Semiconductor
ON Semiconductor
ON Semiconductor
Analog Devices Inc./Maxim Integrated
Analog Devices Inc.
Analog Devices Inc./Maxim Integrated
Phone