MAX1107CUB

lmages are for reference only See Product Specifications

FREE SAMPLE

Analog Devices Inc./Maxim Integrated MAX1107CUB

HIGH-RELIABILITY-COMPONENTS
Part No.:
MAX1107CUB
Manufacturer:
Analog Devices Inc./Maxim Integrated
Package:
-
Datasheet:
MAX1107CUB.pdf
Description:
LOW-POWER, SERIAL 8-BIT ADC
In Stock:
455
Quantity:
  Add To Cart
For more detailed including pricing and shipping
Quick response, quick quotation
Flash shipment, no worries after sales
Original channel, guarantee of the authentic products

Please send RFQ , we will respond immediately.

Part Number
Quantity
Email / phone number*
Contact Name / Company Name
Comments
  • Purchase and inquiryPurchase and inquiry

    MAX1107CUB this integrated circuit is available in factory sealed anti static packs. at icwhale.com. Please read product page below detail information. including MAX1107CUB price, data-sheet, in-stock availability, technical difficulties. Also. Quickly Enter the access of compare listing to find out replaceable electronic parts. If you want to retrieve comprehensive data for MAX1107CUB to optimize the supply chain (including cross references, life-cycle, parametric, counterfeit risk, obsolescence managements forecasts), please contact to our Tech-supports team.

    Purchase in icwhale.com

    There is no doubt that you may place an order without registering to icwhale.com.

    We strongly suggest you sign in our shop before purchasing as you can track your order real-time tracking.

    Means of Payment in icwhale.com

    For your convenience, we support multiple payment methods in USD, including PayPal, Credit Card, wire transfer. and Alipay.

    RFQ (Request for Quotations) in icwhale.com

    It is recommended to acquire for quotations to get the latest prices and inventories about the parts.

    Our sales will reply to your request by email within 24 hours.

    Warm reminder

    1. You'll receive an order information email in your email inbox. (Please remember to check the spam folder if you didn't hear from us).

    2. Since inventories and prices may fluctuate to some extent, the sales manager is going to reconfirm the order and let you know if there are any updates.

    Shipping & Handling

    Shipping fee starts at $35, but some countries will exceed $35. For example (South Africa, Brazil, India, Pakistan, Israel, etc.)

    The basic freight (for package ≤0.5kg or corresponding volume) depends on the time zone and countries.

    Shipping Method

    Currently, our products are shipped through DHL, FedEx, SF, UPS and China Post.

    Order Tracking for International Orders

    Once your order has been shipped, the tracking number will be sent to the email address registered to your account. This information can also be viewed when logged into your account in the "my account" page.

    MAX1107CUB informationMAX1107CUB information

    Views:

    The application and technological advancement of MAX1107CUB in specific industries

    MAX1107CUB is an analog-to-digital converter (ADC) integrated circuit (IC) with eight analog input channels, ideal for precision measurement applications. It offers high accuracy, low power consumption, and small footprint, making it suitable for diverse industries.

    Application Scenario:

    In the medical field, MAX1107CUB finds extensive use in patient monitoring systems, particularly in electrocardiography (ECG) devices.

    Circuit Design:

    To design an ECG monitoring system using MAX1107CUB, adhere to the following guidelines:

    1. Sensor Interface:

    Connect ECG electrodes to the analog input channels of MAX1107CUB to capture the electrical signals generated by the heart. Ensure proper signal conditioning circuits, such as instrumentation amplifiers and filters, are incorporated to enhance signal quality.

    2. Sampling and Conversion:

    Configure MAX1107CUB to sample and convert the analog signals into digital data with the desired resolution and sampling rate. Utilize the built-in features of the IC, such as internal reference voltage and programmable gain amplifier, to optimize signal acquisition.

    3. Data Processing:

    Process the digitized ECG data using digital signal processing (DSP) techniques to extract relevant information, such as heart rate, waveform morphology, and cardiac abnormalities. Employ algorithms for noise reduction and artifact removal to enhance diagnostic accuracy.

    4. Display and Analysis:

    Display the processed ECG signals on a graphical user interface (GUI) for real-time visualization and analysis. Implement features like waveform zooming, parameter measurement, and arrhythmia detection to assist healthcare professionals in clinical decision-making.

    5. Connectivity and Storage:

    Integrate connectivity options, such as Bluetooth or Wi-Fi, to transmit ECG data to remote monitoring stations or electronic health record (EHR) systems for further analysis and storage. Incorporate data encryption and authentication mechanisms to ensure data security and privacy.

    Considerations:

    When designing the ECG monitoring system, consider the following factors:

    - Electrode Placement: Ensure correct placement of ECG electrodes on the patient's body to capture accurate cardiac signals.

    - Signal Quality: Minimize noise and interference by employing proper shielding techniques and avoiding electromagnetic sources.

    - Regulatory Compliance: Verify compliance with medical device regulations, such as FDA guidelines, for safety and performance standards.

    - Power Consumption: Optimize power management circuits to prolong battery life and ensure continuous operation of the monitoring system.

    - User Interface: Design an intuitive and user-friendly interface for healthcare professionals to facilitate seamless operation and interpretation of ECG data.

    MAX1107CUB FAQ

    1. How to order MAX1107CUB on icwhale.com?

    Currently, icwhale.com only provide peer-to-peer order processing. While you submit the RFQ, our professional agent will contact you with the competitive prices in the global market, and our agent will prompt you to finish the order if you accept our offers.

    2. How does icwhale.com guarantee that MAX1107CUB is from the original manufacturer or authorized agents?

    We have a professional and experienced quality control team to strictly verify and test the MAX1107CUB. All suppliers must pass our qualification reviews before they can publish their products including MAX1107CUB on icwhale.com; we pay more attention to the channels and quality of MAX1107CUB products than any other customer. We strictly implement supplier audits, so you can purchase with confidence.

    3. Are the MAX1107CUB price and inventory displayed accurate?

    The price and inventory of MAX1107CUB fluctuates frequently and cannot be updated in time, it will be updated periodically within 24 hours. And, our quotation usually expires after 5 days.

    4. What forms of payment are accepted?

    Wire Transfer, PayPal, Alipay, Wechat, Credit Card, Western Union, MoneyGram, and Escrow are all acceptable.

    Warm Tips: Some orders in certain payment forms may require handling fee.

    5. How is the shipping arranged?

    Customers can choose industry-leading freight companies, including DHL, UPS, FedEx, TNT, and Registered Mail. Shipping insurance is also available.

    Once your order has been processed for shipment, our salesperson will send you an email advising you of the shipping status and tracking number.

    Warm Tips: It may take up to 24 hours for the carriers to display tracking information. Usually, express delivery takes 3-5 days, and registered mail takes 25-60 days.

    6. What is the process for return or replacement of MAX1107CUB?

    All goods will implement Pre-Shipment Inspection (PSI), selected at random from all batches of your order to do a systematic inspection before arranging the shipment. If there is something wrong with the MAX1107CUB we delivered, we will accept the replacement or return of the MAX1107CUB only when all of the below conditions are fulfilled:

    (1)Such as a deficiency in quantity, delivery of wrong items, and apparent external defects (breakage and rust, etc.), and we acknowledge such problems.

    (2)We are informed of the defect described above within 90 days after the delivery of MAX1107CUB.

    (3)The PartNo is unused and only in the original unpacked packaging.

    Two processes to return the products:

    (1)Inform us within 90 days

    (2)Obtain Requesting Return Authorizations

    7.How to contact us to get technical supports, such as MAX1107CUB pin diagram, MAX1107CUB datasheet?

    If you need any after-sales service, please do not hesitate to contact us.

    Hot Products

    Home

    Home

    Products

    Products

    Phone

    Phone

    Contact Us

    Contact