ADS1198CZXGR

lmages are for reference only See Product Specifications

FREE SAMPLE

Texas Instruments ADS1198CZXGR

HIGH-RELIABILITY-COMPONENTS
Part No.:
ADS1198CZXGR
Manufacturer:
Texas Instruments
Package:
64-LFBGA
Datasheet:
ADS1198CZXGR.pdf
Description:
IC AFE 8 CHAN 16BIT 64NFBGA
In Stock:
1980
Quantity:
  Add To Cart
For more detailed including pricing and shipping
Quick response, quick quotation
Flash shipment, no worries after sales
Original channel, guarantee of the authentic products

Please send RFQ , we will respond immediately.

Part Number
Quantity
Email / phone number*
Contact Name / Company Name
Comments
  • Purchase and inquiryPurchase and inquiry

    ADS1198CZXGR this integrated circuit is available in factory sealed anti static packs. at icwhale.com. Please read product page below detail information. including ADS1198CZXGR price, data-sheet, in-stock availability, technical difficulties. Also. Quickly Enter the access of compare listing to find out replaceable electronic parts. If you want to retrieve comprehensive data for ADS1198CZXGR to optimize the supply chain (including cross references, life-cycle, parametric, counterfeit risk, obsolescence managements forecasts), please contact to our Tech-supports team.

    Purchase in icwhale.com

    There is no doubt that you may place an order without registering to icwhale.com.

    We strongly suggest you sign in our shop before purchasing as you can track your order real-time tracking.

    Means of Payment in icwhale.com

    For your convenience, we support multiple payment methods in USD, including PayPal, Credit Card, wire transfer. and Alipay.

    RFQ (Request for Quotations) in icwhale.com

    It is recommended to acquire for quotations to get the latest prices and inventories about the parts.

    Our sales will reply to your request by email within 24 hours.

    Warm reminder

    1. You'll receive an order information email in your email inbox. (Please remember to check the spam folder if you didn't hear from us).

    2. Since inventories and prices may fluctuate to some extent, the sales manager is going to reconfirm the order and let you know if there are any updates.

    Shipping & Handling

    Shipping fee starts at $35, but some countries will exceed $35. For example (South Africa, Brazil, India, Pakistan, Israel, etc.)

    The basic freight (for package ≤0.5kg or corresponding volume) depends on the time zone and countries.

    Shipping Method

    Currently, our products are shipped through DHL, FedEx, SF, UPS and China Post.

    Order Tracking for International Orders

    Once your order has been shipped, the tracking number will be sent to the email address registered to your account. This information can also be viewed when logged into your account in the "my account" page.

    ADS1198CZXGR informationADS1198CZXGR information

    Views:

    The application and technological advancement of ADS1198CZXGR in specific industries

    ADS1198CZXGR is a highly integrated, multichannel, simultaneous-sampling, 24-bit, delta-sigma (ΔΣ) analog-to-digital converter (ADC) designed for high-precision medical and industrial applications.

    Application Scenario:

    In the medical industry, ADS1198CZXGR plays a crucial role in electrocardiogram (ECG) monitoring systems, enabling accurate acquisition and processing of bioelectric signals for diagnostic purposes.

    Circuit Design:

    To design an ECG monitoring system using ADS1198CZXGR, follow these steps:

    1. Electrode Connection:

    Connect electrodes to the patients' skin to capture bioelectric signals, such as ECG waveforms. Ensure proper electrode placement and skin preparation for reliable signal acquisition.

    2. Signal Conditioning:

    Utilize front-end signal conditioning circuits to amplify and filter the weak bioelectric signals before feeding them into ADS1198CZXGR. This ensures optimal signal-to-noise ratio and signal quality.

    3. Data Acquisition:

    Configure ADS1198CZXGR to simultaneously sample multiple channels, capturing the ECG signals with high precision and resolution. Employ appropriate sampling rates and filtering techniques to extract relevant diagnostic information.

    4. Digital Processing:

    Process the digitized ECG signals using digital signal processing (DSP) algorithms to detect cardiac abnormalities, such as arrhythmias or ischemia. Implement filtering, feature extraction, and classification algorithms for accurate diagnosis.

    5. Data Transmission:

    Transmit the processed ECG data to a central monitoring station or healthcare provider for real-time analysis and interpretation. Utilize communication interfaces, such as SPI or UART, to interface ADS1198CZXGR with the data transmission module.

    Considerations:

    When designing the ECG monitoring system, it's essential to consider:

    - Patient Safety: Ensure that the electrodes and electrical connections comply with medical safety standards to prevent electrical hazards to the patients.

    - Noise Immunity: Shield the signal acquisition and processing circuitry to minimize interference from external sources, such as power line noise or electromagnetic interference (EMI).

    - Calibration and Validation: Calibrate ADS1198CZXGR periodically to maintain measurement accuracy and validate the system performance against reference standards and clinical data.

    - Power Efficiency: Optimize power management techniques to minimize power consumption and extend battery life, especially for portable or wearable ECG monitoring devices.

    - Regulatory Compliance: Ensure compliance with medical device regulations, such as FDA guidelines in the United States or CE marking requirements in Europe, for market approval and patient safety.

    ADS1198CZXGR FAQ

    1. How to order ADS1198CZXGR on icwhale.com?

    Currently, icwhale.com only provide peer-to-peer order processing. While you submit the RFQ, our professional agent will contact you with the competitive prices in the global market, and our agent will prompt you to finish the order if you accept our offers.

    2. How does icwhale.com guarantee that ADS1198CZXGR is from the original manufacturer or authorized agents?

    We have a professional and experienced quality control team to strictly verify and test the ADS1198CZXGR. All suppliers must pass our qualification reviews before they can publish their products including ADS1198CZXGR on icwhale.com; we pay more attention to the channels and quality of ADS1198CZXGR products than any other customer. We strictly implement supplier audits, so you can purchase with confidence.

    3. Are the ADS1198CZXGR price and inventory displayed accurate?

    The price and inventory of ADS1198CZXGR fluctuates frequently and cannot be updated in time, it will be updated periodically within 24 hours. And, our quotation usually expires after 5 days.

    4. What forms of payment are accepted?

    Wire Transfer, PayPal, Alipay, Wechat, Credit Card, Western Union, MoneyGram, and Escrow are all acceptable.

    Warm Tips: Some orders in certain payment forms may require handling fee.

    5. How is the shipping arranged?

    Customers can choose industry-leading freight companies, including DHL, UPS, FedEx, TNT, and Registered Mail. Shipping insurance is also available.

    Once your order has been processed for shipment, our salesperson will send you an email advising you of the shipping status and tracking number.

    Warm Tips: It may take up to 24 hours for the carriers to display tracking information. Usually, express delivery takes 3-5 days, and registered mail takes 25-60 days.

    6. What is the process for return or replacement of ADS1198CZXGR?

    All goods will implement Pre-Shipment Inspection (PSI), selected at random from all batches of your order to do a systematic inspection before arranging the shipment. If there is something wrong with the ADS1198CZXGR we delivered, we will accept the replacement or return of the ADS1198CZXGR only when all of the below conditions are fulfilled:

    (1)Such as a deficiency in quantity, delivery of wrong items, and apparent external defects (breakage and rust, etc.), and we acknowledge such problems.

    (2)We are informed of the defect described above within 90 days after the delivery of ADS1198CZXGR.

    (3)The PartNo is unused and only in the original unpacked packaging.

    Two processes to return the products:

    (1)Inform us within 90 days

    (2)Obtain Requesting Return Authorizations

    7.How to contact us to get technical supports, such as ADS1198CZXGR pin diagram, ADS1198CZXGR datasheet?

    If you need any after-sales service, please do not hesitate to contact us.

    Hot Products

    Home

    Home

    Products

    Products

    Phone

    Phone

    Contact Us

    Contact