MSP430F5522IRGCT

lmages are for reference only See Product Specifications

FREE SAMPLE

Texas Instruments MSP430F5522IRGCT

HIGH-RELIABILITY-COMPONENTS
Part No.:
MSP430F5522IRGCT
Manufacturer:
Texas Instruments
Package:
64-VFQFN Exposed Pad
Datasheet:
MSP430F5522IRGCT.pdf
Description:
IC MCU 16BIT 32KB FLASH 64VQFN
In Stock:
2171
Quantity:
  Add To Cart
For more detailed including pricing and shipping
Quick response, quick quotation
Flash shipment, no worries after sales
Original channel, guarantee of the authentic products

Please send RFQ , we will respond immediately.

Part Number
Quantity
Email / phone number*
Contact Name / Company Name
Comments
  • Purchase and inquiryPurchase and inquiry

    MSP430F5522IRGCT this integrated circuit is available in factory sealed anti static packs. at icwhale.com. Please read product page below detail information. including MSP430F5522IRGCT price, data-sheet, in-stock availability, technical difficulties. Also. Quickly Enter the access of compare listing to find out replaceable electronic parts. If you want to retrieve comprehensive data for MSP430F5522IRGCT to optimize the supply chain (including cross references, life-cycle, parametric, counterfeit risk, obsolescence managements forecasts), please contact to our Tech-supports team.

    Purchase in icwhale.com

    There is no doubt that you may place an order without registering to icwhale.com.

    We strongly suggest you sign in our shop before purchasing as you can track your order real-time tracking.

    Means of Payment in icwhale.com

    For your convenience, we support multiple payment methods in USD, including PayPal, Credit Card, wire transfer. and Alipay.

    RFQ (Request for Quotations) in icwhale.com

    It is recommended to acquire for quotations to get the latest prices and inventories about the parts.

    Our sales will reply to your request by email within 24 hours.

    Warm reminder

    1. You'll receive an order information email in your email inbox. (Please remember to check the spam folder if you didn't hear from us).

    2. Since inventories and prices may fluctuate to some extent, the sales manager is going to reconfirm the order and let you know if there are any updates.

    Shipping & Handling

    Shipping fee starts at $35, but some countries will exceed $35. For example (South Africa, Brazil, India, Pakistan, Israel, etc.)

    The basic freight (for package ≤0.5kg or corresponding volume) depends on the time zone and countries.

    Shipping Method

    Currently, our products are shipped through DHL, FedEx, SF, UPS and China Post.

    Order Tracking for International Orders

    Once your order has been shipped, the tracking number will be sent to the email address registered to your account. This information can also be viewed when logged into your account in the "my account" page.

    MSP430F5522IRGCT informationMSP430F5522IRGCT information

    Views:

    The working principle and core technical features of MSP430F5522IRGCT


    MSP430F5522IRGCT is a microcontroller chip renowned for its efficient operation and versatile functionality, widely used in embedded systems for diverse applications. It incorporates a high-performance 16-bit RISC CPU, rich peripherals, and ultra-low power consumption.

    Application Scenario:

    In portable medical devices, MSP430F5522IRGCT plays a crucial role in monitoring vital signs such as heart rate and blood pressure, ensuring accurate measurements and efficient power management for prolonged battery life.

    Circuit Design:

    To design a portable medical monitoring device using MSP430F5522IRGCT, follow these guidelines:

    1. Sensor Integration:

    Integrate sensors for vital signs monitoring, such as ECG sensors and blood pressure sensors, with MSP430F5522IRGCT. Utilize the built-in ADCs for analog signal processing and precise measurement.

    2. Power Management:

    Implement efficient power management schemes leveraging the low power modes of MSP430F5522IRGCT to extend battery life. Utilize features like standby mode and low-power timers for optimal power utilization.

    3. Data Processing:

    Process sensor data using the powerful CPU of MSP430F5522IRGCT for real-time analysis and monitoring. Implement algorithms for heartbeat detection, blood pressure calculation, and anomaly detection.

    4. User Interface:

    Design a user-friendly interface with LCD displays or LEDs to present vital signs data to the user. Utilize GPIO pins for interfacing with display components and user input devices like buttons.

    5. Communication:

    Enable communication interfaces such as UART or I2C for data exchange with external devices or central monitoring systems. Configure the relevant GPIO pins for serial communication and ensure data integrity.

    Performance Enhancement:

    To enhance system performance and efficiency, consider the following strategies:

    - Firmware Optimization: Optimize firmware algorithms to minimize CPU utilization and maximize battery life.

    - Peripheral Utilization: Efficiently utilize the rich set of peripherals of MSP430F5522IRGCT for tasks such as data acquisition, processing, and communication.

    - Low Power Design: Leverage the ultra-low power features of MSP430F5522IRGCT to minimize power consumption during idle and active modes, extending battery life in portable applications.

    - Real-Time Monitoring: Implement real-time monitoring and alarm systems using the advanced features of MSP430F5522IRGCT to ensure timely detection of abnormalities in vital signs.

    - System Integration: Integrate MSP430F5522IRGCT seamlessly into the overall system architecture, ensuring compatibility and interoperability with other components for efficient operation.

    MSP430F5522IRGCT FAQ

    1. How to order MSP430F5522IRGCT on icwhale.com?

    Currently, icwhale.com only provide peer-to-peer order processing. While you submit the RFQ, our professional agent will contact you with the competitive prices in the global market, and our agent will prompt you to finish the order if you accept our offers.

    2. How does icwhale.com guarantee that MSP430F5522IRGCT is from the original manufacturer or authorized agents?

    We have a professional and experienced quality control team to strictly verify and test the MSP430F5522IRGCT. All suppliers must pass our qualification reviews before they can publish their products including MSP430F5522IRGCT on icwhale.com; we pay more attention to the channels and quality of MSP430F5522IRGCT products than any other customer. We strictly implement supplier audits, so you can purchase with confidence.

    3. Are the MSP430F5522IRGCT price and inventory displayed accurate?

    The price and inventory of MSP430F5522IRGCT fluctuates frequently and cannot be updated in time, it will be updated periodically within 24 hours. And, our quotation usually expires after 5 days.

    4. What forms of payment are accepted?

    Wire Transfer, PayPal, Alipay, Wechat, Credit Card, Western Union, MoneyGram, and Escrow are all acceptable.

    Warm Tips: Some orders in certain payment forms may require handling fee.

    5. How is the shipping arranged?

    Customers can choose industry-leading freight companies, including DHL, UPS, FedEx, TNT, and Registered Mail. Shipping insurance is also available.

    Once your order has been processed for shipment, our salesperson will send you an email advising you of the shipping status and tracking number.

    Warm Tips: It may take up to 24 hours for the carriers to display tracking information. Usually, express delivery takes 3-5 days, and registered mail takes 25-60 days.

    6. What is the process for return or replacement of MSP430F5522IRGCT?

    All goods will implement Pre-Shipment Inspection (PSI), selected at random from all batches of your order to do a systematic inspection before arranging the shipment. If there is something wrong with the MSP430F5522IRGCT we delivered, we will accept the replacement or return of the MSP430F5522IRGCT only when all of the below conditions are fulfilled:

    (1)Such as a deficiency in quantity, delivery of wrong items, and apparent external defects (breakage and rust, etc.), and we acknowledge such problems.

    (2)We are informed of the defect described above within 90 days after the delivery of MSP430F5522IRGCT.

    (3)The PartNo is unused and only in the original unpacked packaging.

    Two processes to return the products:

    (1)Inform us within 90 days

    (2)Obtain Requesting Return Authorizations

    7.How to contact us to get technical supports, such as MSP430F5522IRGCT pin diagram, MSP430F5522IRGCT datasheet?

    If you need any after-sales service, please do not hesitate to contact us.

    Hot Products

    Home

    Home

    Products

    Products

    Phone

    Phone

    Contact Us

    Contact